” Peer-reviewed publications in English in the period 1970 to Dec

” Peer-reviewed publications in English in the period 1970 to December 2011 were collected, evaluated by their abstract, and included if they met the inclusion criteria. The criteria involved studies evaluating marginal adaptation of crowns and FDPs through clear experimental protocols. Exclusion criteria selleck chemicals llc involved longitudinal prospective and retrospective clinical evaluations, studies using subjective tactile sensation, and other predefined criteria. A total of 277 papers were identified; only 183 met the inclusion criteria. Direct view technique

was used by 47.5% of the articles followed by cross-sectioning (23.5%), and impression replica (20.2%) techniques. The marginal gap values reported by these techniques varied among individual crown systems and across different systems because of variations in study type (in vivo vs. in vitro), sample size and measurements per specimen, finish line design, and stage at which the marginal gap was measured. There was a substantial lack of consensus relating to marginal adaptation of various crown systems due to differences in testing methods and experimental protocols employed. Direct view technique was the most commonly used method of reproducible results. Also, conducting an experimental set-up of testing a minimum of 30 specimens at 50 measurements per specimen should produce reliable results. Additionally, using a combination of two measurement methods can be useful

in verification of results. “
“In this clinical report, following computer-guided GSI-IX in vitro (3D

Procera Software Planning Program, Nobel Biocare, Yorba Linda, CA) placement and immediate provisionalization of 12 dental implants (NobelSpeedy™ Replace, Nobel Biocare), misfits of the prefabricated screw-retained interim prostheses were noted at several implant-abutment junctions. Nevertheless, adaptation of the misfits was observed 10 days later, after the loosened screws were tightened. While a high mean marginal bone loss of 2.1 mm (range: 1.4 to 3.5 mm) was noted, all implants remained osseointegrated at 3-year follow-up. “
“Purpose: The purpose of this study was to evaluate the color stability of MDX4-4210 maxillofacial elastomer with opacifier addition submitted to chemical disinfection and accelerated aging. Materials and Methods: Ninety specimens were obtained from Silastic MDX4-4210 silicone. The specimens were divided ADP ribosylation factor into three groups (n = 30): Group I: colorless, Group II: barium sulfate opacifier, Group III: titanium dioxide opacifier. Specimens of each group (n = 10) were disinfected with effervescent tablets, neutral soap, or 4% chlorhexidine gluconate. Disinfection was conducted three times a week for 2 months. Afterward, the specimens were submitted to different periods of accelerated aging. Color evaluation was carried out after 60 days (disinfection period) and after 252, 504, and 1008 hours of accelerated aging, using a reflection spectrophotometer. Color alterations were calculated by the CIE L*a*b* system.

Leave a Reply

Your email address will not be published. Required fields are marked *

*

You may use these HTML tags and attributes: <a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <strike> <strong>